Metal double knob cylinder
Product description
Communication from hub via RS485 bus to the Online Access Control System (addressable) - access decision in the EAC system
Compatible with all DIN mortice locks, suitable for locks on glass door wings and walls
Main electronics (RFID + radio) in the outside knob - secure electronics inside cylinder core
Freely rotating lock cam
Outside knob free wheeling - inside knob always engaged (not for VERSION= E/ED, ED/ED)
Possibility to store up to 10 emergency cards (only used in case of disconnection from the hub)
LED for status visualisation
|
Approvals: |
CE; fire door up to T90 |
|
Knob versions: |
Fix or demountable knob versions with or without RFID-Reader |
Knob dimensions: |
V2: 43 x 33 mm / V3: 50 x 32 mm (L x Ø) |
|
Knob surface: |
Stainless steel |
|
|
Cylinder length (LENGTH=A/LENGTH=B): |
Basic length 30/30 mm, extendable in 5 mm increments up to 60 mm |
Fixing screw: |
60 or 85 mm |
|
|
Battery: |
1 x Lithium CR2 |
Battery life: |
> 40,000 cycles (for max. 3 years) |
|
|
Radio standard: |
IEEE 802.15.4 (2.4 GHz) |
Encryption (radio communication): |
AES 128 bits |
|
Distance between the RFID-Reader and hub: |
Typical range of 5 m or 25 m depending on the hub type and building environments |
|
|
Class of protection: |
IP 55 |
Operating temperature range: |
0°C to 50°C |
|
|
Status: |
LED (red/green/orange) |
|
RFID Technology: |
iCLASS™/ISO 14443B; MIFARE™ classic; MIFARE™ plus; MIFARE™ DESFire™ EV1; HID PROX/ EM410x |
RFID reading: |
UID / Sektor / Block / Application / File |
|
Scanning range: |
< 4 cm |
|
|
Interface: |
Micro USB Firmware download (V3 only) |
Download